Slide background
Slide background
Slide background
Slide background
Slide background
Slide background
Slide background
Slide background
  • New

ATEX Temperature Controller (Zone 1/2-21/22) for Industrial Heating

23-4258
The ATEX Temperature Controller-Limiter and Power Selector is the indispensable tool for safe thermal control in potentially explosive environments (zones 1/2 and 21/22). It offers complete temperature management thanks to its dual function of precise regulation and safety limitation, complemented by a power selector for the optimization of ATEX heating elements. Safety is at the heart of its design, incorporating Ex-i intrinsic safety for Pt100 sensors and galvanic isolation for maximum reliability. With an intuitive display, a robust IP 64 housing made of aluminium and high precision (< 1 K accuracy), this device is ideal for heating drums, tanks or pipes in sensitive industries (chemicals, petrochemicals). It ensures regulatory compliance and the protection of your installations in explosive atmospheres.
€3,590.00
Tax included
Supplier Direct Delivery - 7-Day Shipping

Il n'y a pas encore d'avis.

Precise Control and Maximizing Safety: The ATEX Temperature Controller-Limiter

Temperature control is a critical requirement in many industrial environments. However, when these areas are classified as potentially explosive atmospheres (ATEX zones), temperature control and limitation require equipment that does not compromise on safety. This ATEX temperature controller-limiter is precisely the answer to the needs of professionals. It offers a complete solution for thermal management, while incorporating an essential power selector function. This versatility simplifies installation and operation, ensuring compliance and operational efficiency. Designed to fit multitanks.com's entire range of ATEX heating products, this device is a pillar for industrial process safety in hazardous areas.

 

ATEX Compliance and Intrinsic Safety: The Absolute Requirement in Hazardous Areas

The major specificity of this device lies in its design for ATEX zones 1/2 (gas) and 21/22 (dust). Installation is permitted both inside and outside of these potentially explosive environments. To ensure maximum protection, this regulator uses the Ex-i (intrinsically safe) protection type for the connection of the Pt100 sensors. This mechanism limits the electrical energy in the sensor circuit to a level lower than that needed to cause an explosion. Galvanic isolation of the Pt100 DIN EN 60751 resistance thermometer in a 3 or 2-wire circuit reinforces this safety. In addition to this protection, the product comes with extensive documentation for the explosion protection manual, providing operators and safety managers with all the information needed for compliant use.

 

Key Features: Built-in Power Regulation, Limiting, and Selection

This controller goes beyond just regulating temperature. It acts as a true complete thermal management system. The user benefits from a dual solution: precise temperature control and safety limitation. The addition of the power selector function allows the heating intensity to be adjusted as needed, contributing to energy optimization and extending the life of the heating element. For optimal use, a built-in temperature switch is included, ensuring automatic deactivation around 90°C when needed. The clear measurement display via 7-segment LEDs ensures a quick and intuitive reading of the parameters. In terms of performance, the device has a switching point accuracy of less than 1 K and a regulator hysteresis of 2 K, which ensures reliability in maintaining the target temperature.

 

Simplified Installation and Maintenance for Everyday Use

The device is designed to be both user-friendly and intuitive. The aluminium housing with base plate mounting ensures robustness suitable for harsh industrial environments, with an IP 64 degree of protection according to EN 60529, ensuring good resistance to dust and splashing water. The connectors are designed to facilitate installation: three screw cables are provided (1x M25 for the power supply, 1x M25 for the heating cable and 1x M16 for the sensor cable). For maintenance, accessibility is essential: the fuse of the control circuit is accessible internally via the terminal. System safety is also ensured by sensor breakage and short-circuit notification, allowing technicians to quickly identify and correct any potential issues, minimizing production downtime.

 

Use Cases and Best Practices

This controller is suitable for any application requiring heating in ATEX zones with rigorous monitoring. It is commonly found in the chemical, petrochemical, pharmaceutical industries, or in the agri-food sector for the treatment of explosive powders.

  • ATEX Drum and Tank Heating: Coupled with an ATEX heating jacket or an ATEX IBC tank heater, it allows fluids to be maintained at an optimal viscosity or to avoid freezing, while strictly respecting the safety temperature limits. The power selector function is ideal for adapting the heating to variations in volume or ambient temperature.

  • Pipe Freeze Protection: Used with an ATEX self-regulating heating cable, it ensures that the temperature never drops below a critical threshold, preventing damage to installations without ever overheating, which is vital in an area at risk of explosion.

  • Temperature Maintenance Process: In production processes requiring precise maintenance (slow cooking, chemical activation), this controller ensures that the temperature remains within the tolerance window, thanks to its high accuracy and its alarm relay from 5A to 250V with CO (Change Over) contact that can be wired to immediately signal any exceedance or anomaly.

The best way to use this regulator is to configure it in tandem with the intrinsically safe Pt100 sensor, ensuring that the alarm cut-off parameters are set according to the maximum requirements of the substance present in the ATEX area, using the limiter function as the ultimate safety barrier.

 

Detailed Technical Specifications of the ATEX Controller

For a quick overview of the product specifications, here is a summary table of the technical data:

CharacteristicsSpecifications
Power supply230 VAC (50-60 Hz)
Maximum Charging Current25 A (25 A external protection required)
Compatible SensorPT100 (EX-i), 3 or 2 wire circuit
Intrinsically safeEx ib IIC (Uo= 6.3 V, Io= 22 mA, Po= 35 mW max. Co= 1.5 μF, Lo= 10 mH) / Ex ib IIB (Uo= 6.3 V, Io= 22 mA, Po= 35 mW max. Co= 8.2 μF, Lo= 10 mH)
Degree of ProtectionIP 64 according to EN 60529
Measuring Range0...450 °C
Precision Switching Point< 1 K
Hysteresis of the Regulator2 K
Alarm Relay Output1 CO (Change Over) contact from 5A to 250V
Cable Connection1x M25 (Power Supply), 1x M25 (Heating Cable), 1x M16 (Sensor Cable)
Dimensions (LxWxH) / Weight260 x 160 x 135 mm / ca. 6.0 kg
MaterialAluminum (housing), base plate mount
Supplemental ProtectionBuilt-in temperature switch (~90 °C), Rupture notice and sensor short circuit
Multitanks
23-4258

Technical data sheet

Summary#1
Temperature control is a critical requirement in many industrial environments. However, when these zones are classified as potentially explosive atmospheres (ATEX zones), temperature regulation and limitation is required
Summary#2
It offers a complete solution for thermal management, while incorporating an essential power selector function. This versatility simplifies installation and operation, ensuring compliance and operational efficiency. C
Summary#3
The major specificity of this device lies in its design for ATEX zones 1/2 (gas) and 21/22 (dust). Installation is permitted both inside and outside of these potentially explosive environments. To ensure a high level of
Summary#4
Galvanic isolation of the Pt100 DIN EN 60751 resistance thermometer in a 3 or 2-wire circuit reinforces this safety. In addition to this protection, the product comes with extensive documentation for the Slam Protection Manual.
Summary#5
The device is designed to be both user-friendly and intuitive. The aluminium housing with base plate mounting ensures robustness suitable for harsh industrial environments, with an IP 64 degree of protection according to EN 60529, ass

You might also like

  • Container Heater IBC ATEX 1000L - Frost Protection and Temperature Maintenance
    €6,390.00
  • Insulating Cover IBC 1000L IP65 - Reduces Heat Loss and Speeds Up Heating
    €1,025.00

10 other products in the same category: