      Plasteau 150-liter fire safety chest specially designed to store sand and neutralizing agents near fuel installations. Manufactured in red anti-UV treated polyethylene, this chest resists weather and corrosion.

      Meets decree 261 bis requirements for fuel depots and gas stations. Reliable and aesthetic solution for your fire safety.

      Quantity:
      Product-only, available in about a week
      • Safety guaranteesSafety guarantees100% secure payment
      • Shipping PolicyShipping PolicyResponsive and attentive after-sales service
      • Returns PolicyReturns PolicyFast and secure delivery

      Fire Safety Chest 150 Litres Plasteau (Reference: 300153) represents the reference solution for secure storage of extinguishing and neutralizing agents in fire-risk installations. Manufactured by Plasteau, recognized specialist in safety equipment, this high-density polyethylene chest meets the strictest regulatory requirements. Its robust design and distinctive red color make it an essential fire prevention element for both professionals and individuals.

       


       

      Applications and areas of use

      This fire safety chest finds its place in numerous high-risk environments. Fuel depots, gas stations, automotive garages and mechanical workshops constitute its main application areas. In compliance with decree 261 bis, it must be positioned in immediate proximity to tank filling openings to enable rapid intervention in case of emergency.

      Agricultural operations, transport companies, logistics centers and industrial sites handling flammable substances also benefit from this safety solution. Its 150-liter capacity allows storage of sufficient dry sand or neutralizing agents to handle accidental spills and fire outbreaks. Local authorities adopt it to equip their municipal depots and technical areas.

       


       

      Technical design and materials

      The high-density polyethylene used for manufacturing this chest guarantees exceptional resistance to external constraints. The integrated anti-UV treatment preserves material integrity against intense solar radiation, preventing degradation and premature brittleness. This protection is crucial for outdoor installations exposed to the elements.

      The corrosion resistance of polyethylene allows use in chemically aggressive environments without alteration of mechanical properties. Smooth walls facilitate cleaning and prevent residue accumulation. The standardized red color ensures immediate identification of fire safety equipment, compliant with international visual standards. Optimized dimensions enable efficient storage while maintaining satisfactory handling.

       


       

      Installation and commissioning

      Installation of the fire safety chest requires a strategic location determined by site risk analysis. It must be positioned in immediate proximity to risk areas while remaining accessible even during incidents. A flat and stable surface constitutes the essential prerequisite for durable installation.

      Initial filling is performed with dry sifted sand or specific neutralizing agents according to the nature of products handled on site. The intervention shovel must be maintained within immediate reach, ideally attached to the chest or in a dedicated support. A hermetic lid protects contents from moisture and external contamination.

      Maintenance is limited to periodic checks of fill level, sand quality and general chest condition. Annual cleaning with soapy water preserves the appearance and properties of polyethylene. Sand renewal is performed according to manufacturer recommendations and local regulatory constraints.

       


       

      Expert advice and safety optimization

      The effectiveness of a fire safety system relies on personnel training and regular intervention drills. Each employee must know the exact location of the chest and the procedure for using sand or neutralizing agents. Clear signage and standardized pictograms reinforce equipment visibility.

      Complementarity with other safety equipment like fire extinguishers, fire blankets and absorption kits optimizes emergency response. Association with containment basins and confinement systems creates a multilayer safety barrier particularly effective for sensitive installations.

      Avoid the common error of using wet or contaminated sand, which loses its absorbent properties and may worsen certain types of fires. Seasonal verification before high-risk periods (summer drought, winter frost) guarantees operational availability of equipment. For isolated sites, plan a spare sand stock and automatic alert system to emergency services.

       


       

      Technical specifications

      DetailsSpecifications
      Reference300153
      BrandPlasteau
      Capacity150 litres
      MaterialHigh-density polyethylene
      ColorSafety red
      UV ProtectionIntegrated anti-UV treatment
      ResistanceCorrosion and weather
      ComplianceDecree 261 bis
      ApplicationGas station fire safety
      UsageOutdoor and indoor
      300153

      Specific references

      EAN13
      3760269580787

      3 other products in the same category: