• On sale!
    • Pack
    DC402 Refill Kit with R134a High Pressure Fitting for Duracool / Multicool / Climapure Canisters
    DC402 Refill Kit with R134a High Pressure Fitting for Duracool / Multicool / Climapure Canisters

    DC402 Refill Kit with R134a High Pressure Fitting for Duracool / Multicool / Climapure Canisters

    dc402
    €37.00
    Tax included

    Of which €0.03 eco-tax

    (4/5) out of 23 total ratings
    Read the reviews
    In Stock

    The DC402 Duracool Refill Kit is the essential professional tool for efficiently refilling all automotive air conditioning systems. Compatible with eco-friendly refrigerant gases Duracool, Multicool and Climapure, this complete kit includes a self-piercing valve, universal R12 and R134a fittings (low and high pressure), and a PSI gauge for precise charge control.

    Designed for automotive professionals and demanding consumers, this kit ensures safe and optimal refilling of your air conditioning system, regardless of vehicle type.

    Quantity:
    In Stock 44 Available
    • Safety guaranteesSafety guarantees100% secure payment
    • Shipping PolicyShipping PolicyResponsive and attentive after-sales service
    • Returns PolicyReturns PolicyFast and secure delivery

    DC402 refill kit with R134a high pressure fitting (Reference: dc402) is the complete professional solution for performing automotive air conditioning refills safely. Designed by Duracool, leader in eco-friendly refrigerant gases, this versatile kit adapts to all market vehicles thanks to its universal fittings and integrated measurement system.

     


     

    Professional applications and use cases

    This DC402 refill kit meets the needs of garage owners, automotive mechanics and passionate enthusiasts wishing to maintain the efficiency of their air conditioning system. It is particularly suitable for interventions on older vehicles equipped with R12 systems, modern cars using R134a, as well as for preventive maintenance operations before summer periods.

    The kit allows performing precise top-ups during minor leaks, complete refills after repairs, or pressure checks to diagnose the condition of the refrigeration circuit. Its versatility makes it an essential tool for multi-brand workshops and automotive service centers.

     


     

    Technical specifications and innovation

    The self-piercing valve represents the major innovation of this kit. It attaches directly to Duracool, Multicool and Climapure canisters without requiring specific tools. Its secure piercing mechanism guarantees perfect sealing and prevents gas losses during connection.

    The two sets of fittings provided cover the entire automotive fleet: R12 screw-in fittings for older vehicles and R134a low and high pressure fittings for modern systems. This universal compatibility eliminates the need to purchase multiple specialized kits.

    The integrated PSI gauge provides direct and accurate reading of system pressure. Graduated according to international standards, it allows real-time charge control and prevents damaging overcharges to the compressor.

     


     

    Installation and practical use

    Using the DC402 kit follows a simple and secure protocol. Start by identifying the fitting type of your vehicle (R12 or R134a) and select the appropriate fitting set. Screw the self-piercing valve firmly onto the refrigerant gas canister ensuring connection tightness.

    Before connecting the kit to the vehicle, verify that the engine is stopped and the air conditioning system is off. Connect the hose to the appropriate service port (low pressure for standard top-up, high pressure for complete check). The gauge will immediately indicate circuit pressure.

    To perform the refill, gradually open the canister valve while monitoring pressure evolution. Optimal values vary by vehicle but generally range between 25 and 35 PSI on the low pressure side. Once refilling is complete, close the valve, disconnect the kit and store it in a dry place.

     


     

    Expert advice and product synergies

    To optimize the efficiency of your interventions, combine the DC402 kit with Duracool 12a refrigerant gases, a high-performance and economical eco-friendly solution. These hydrocarbon gases offer excellent cooling power while respecting the environment, unlike traditional HFCs.

    Before any refill, systematically perform a leak check of the circuit with an appropriate leak detector. An unrepaired leak will make refilling temporary and costly. Also consider changing the dryer filter during major interventions.

    For professionals, complete your equipment with high-quality refill hoses and an old fluid recovery system. This environmentally respectful approach enhances your expertise with customers.

    Seasonal tip: plan refills in late winter or early spring to anticipate summer needs and avoid air conditioning breakdowns during hot weather.

     


     

    Technical characteristics

    DetailsSpecifications
    Manufacturer referenceDC402
    BrandDuracool
    Valve typeSelf-piercing secure
    Fittings includedR12 (screw-in) + R134a LP/HP
    GaugeIntegrated PSI graduation
    Gas compatibilityDuracool, Multicool, Climapure
    ApplicationAutomotive air conditioning
    UsageProfessional and consumer
    Pressure range0-150 PSI
    Canister connectionUniversal standard threading
    dc402
    44 Items

    Specific references

    EAN13
    3760235768461

    Customers who bought this product also bought:

    11 other products in the same category: